Yonker PV-L4A Vital Signs Monitor UAE – Compact Portable Monitor

Prime Medical Devices supplies the Yonker PV-L4A vital signs monitor UAE, a compact and portable device for hospitals, emergency rooms, ambulances and day-care wards. It combines accurate physiological monitoring with lightweight portability, supporting Adult, Pediatric and Neonatal patients with optional EtCO₂ and IBP modules.

our services

Key Features

  • Compact and lightweight bedside / transport design
  • Measures NIBP, SpO₂, PR, RESP, TEMP
  • Adult / Pediatric / Neonatal modes
  • Large clear LCD display for ward/ER visibility
  • Audible & visual alarms for safety
  • Built-in battery for mobile/ambulance use

Technical Specifications

Display & Design
  • 10.4″ high-resolution TFT color screen (800 × 600 pixels) with clear numeric and waveform display
  • Compact and lightweight form factor for easy transport between wards or ambulances
  • Fan-less medical design for silent operation in ICU and recovery environments
  • Built-in handle and multiple mounting options (trolley / wall / bedside)
  • Front panel LED indicators for power, alarms, and battery status
Electrical & Safety Classification
  • Power supply: AC 100 – 240 V 50/60 Hz
  • Built-in lithium-ion battery (≥ 4400 mAh) providing up to 4 hours of continuous monitoring
  • Classification: Class I medical equipment, BF/CF applied parts
  • Protection type: Continuous operation, IEC 60601-1 compliant
  • EMC conformity per IEC 60601-2 and CISPR standards
Measured Parameters (Standard Configuration)
ECG
  • 3-lead / 5-lead ECG monitoring with diagnostic, monitor, and surgical modes
  • Frequency response: 0.05 – 130 Hz (diagnostic) | 0.5 – 40 Hz (monitor) | 1 – 20 Hz (surgery)
  • CMRR ≥ 105 dB; ST-segment analysis supported
  • Sweep speeds: 12.5 / 25 / 50 mm/s
SpO₂ & Pulse
  • Measurement range: 0 – 100 % | Accuracy ± 2 % (70 – 100 %)
  • Pulse rate range: 30 – 300 bpm | Accuracy ± 3 bpm
  • Low-perfusion detection ≥ 0.5 % | Update time ≤ 5 s
Respiration
  • Thoracic impedance method | Adult 0 – 120 BrPM | Neonate 0 – 150 BrPM
  • Accuracy ± 2 BrPM within 7 – 120 BrPM
NIBP
  • Method: Oscillometric | Modes: Manual / Auto / STAT
  • Adult range: SYS 40 – 270 | DIA 10 – 215 | MAP 20 – 235 mmHg
  • Accuracy: ± 3 mmHg
Temperature
  • Range 0 – 50 °C | Accuracy ± 0.1 °C | Dual channels TEMP 1 / TEMP 2
Optional Modules (Advanced Configuration)
EtCO₂ (Mainstream / Sidestream)
  • Measurement range: 0 – 19.7 % (0 – 150 mmHg)
  • Resolution 0.1 % | Accuracy ± 2 mmHg (0 – 40 mmHg), ± 5 % reading (41 – 70 mmHg)
  • Respiration rate 2 – 150 BrPM | Accuracy ± 1 BrPM
  • Response time ≤ 3 s (mainstream) | Sampling flow ≤ 200 mL/min (sidestream)
IBP (Dual Channel)
  • Measurement sites: ART / PA / CVP / RAP / LAP / ICP etc.
  • Range: −50 to +300 mmHg | Resolution 1 mmHg | Accuracy ± 2 % or ± 1 mmHg
Thermal Recorder (Optional)
  • Built-in 50 mm thermal printer | 3 trace output
  • Print speed: 12.5 / 25 / 50 mm/s
  • Modes: Real-time, Review, Alarm event print, NIBP list
Data Storage & Review
  • Trend data up to 7 days (24 h per day)
  • NIBP records: 400 measurements
  • Alarm review memory: 100 events
  • Waveform playback: 100 minutes (6000 s)
Alarms & System Functions
  • Technical and physiological alarms with audible + visual signals
  • Alarm priorities: High / Medium / Low with distinct tones
  • User-defined limits and alarm delays
  • Manual silence / auto reset options
  • Event and alarm logs stored for trend review
Environmental Conditions
  • Operating: 0 °C – 40 °C | ≤ 85 % RH
  • Storage/transport: −20 °C – 60 °C | ≤ 93 % RH
  • Altitude range: up to 5000 m (non-condensing environment)
Included Accessories
  • ECG lead cable set
  • SpO₂ finger sensor
  • NIBP cuff & tubing
  • Temperature probe
  • Power cable & battery
  • User manual
Application - Yonker PV-L4A Vital Signs Monitor - Prime Medical Devices
our services

Applications

  • Emergency Rooms (ER)
  • Hospital Wards & Observation Units
  • Outpatient & OPD Clinics
  • Ambulance & Transport
  • Day-care Treatment Units
Request Brochure & Quotation

The official Yonker PV-L4A brochure is provided on request.
Send “PV-L4A Brochure” on WhatsApp to receive file + quotation.

Looking for competitive pricing for Yonker PV-L4A vital signs monitor UAE or export support to Africa?
Send “PV-L4A Brochure” on WhatsApp to receive the official PDF and quotation.

Request Quote on WhatsApp
Email Us
Visit our Contact Page for details.

Request Brochure & Quotation

All Yonker vital signs monitors from Prime Medical Devices meet
ISO 13485:2016 Medical Device Standards.

Looking for competitive pricing for Yonker PV-L4A in UAE or export to Africa?
Send the model name, quantity and destination to receive an official quotation.

FAQ – Yonker PV-L4A

do you have a question?

No. This monitor is designed for ward, ER, OPD and ambulance environments. For ICU use, see Yonker YK-8000D or PM-LP15A.

Yes. It supports adult, pediatric and neonatal modes.

Yes. The official Yonker brochure and technical details are shared on request via WhatsApp or Email.

Yes. Export for this model is available. Packing and documentation are arranged after order confirmation.

Official quotation is shared after you send model name, quantity and destination.